FEATURES
FILAMENT REPLACEMENT LEDs - BA9s
l
**Part No. 214-501-75-50 RIA 12 Approved.
Certificate No. RR-TRS-97-161 A
214 SERIES
PACK QUANTITY = 20 PIECES
l
l
l
Direct replacement for T3¼ BA9s incandescent
Durable to shock and vibration
Centre contact is Anode (Centre contact Cathode is
also available)
l
AC Versions available
SPECIFICATIONS
Ordering Information & Typical Technical Characteristics (Ta = 25°C)
Mean Time Between Failure = 100,000 Hours. Luminous intensity figures refer to the unmodified discrete LED.
PART NUMBER
COLOUR
LENS
VOLTAGE
DC
CURRENT
DC
LUMINOUS
INTENSITY
lv@20mA
WAVE
LENGTH
λp
OPERATING
TEMP
STORAGE
TEMP
Vopr
lopr
Topr
Tstg
HIGH INTENSITY
214-501-22-50
214-521-22-50
214-532-22-50
214-930-22-50
214-997-22-50
214-501-75-50
214-521-75-50
214-532-75-50
214-930-75-50
214-997-75-50
UNITS
Red
Water Clear
Water Clear
Water Clear
Water Clear
Water Clear
Water Clear
Water Clear
Water Clear
Water Clear
Water Clear
24
19
19
20
20
20
5
11000
16000
23000
7000
624
591
527
470
*
-40 ~ +95^
-40 ~ +95^
-40 ~ +95^
-40 ~ +95^
-40 ~ +95^
-40 ~ +95^
-40 ~ +95^
-40 ~ +95^
-40 ~ +95^
-40 ~ +95^
0C
-40 ~ +100
-40 ~ +100
-40 ~ +100
-40 ~ +100
-40 ~ +100
-40 ~ +100
-40 ~ +100
-40 ~ +100
-40 ~ +100
-40 ~ +100
0C
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yellow
Green
Blue
24
24
24
Cool White
Red
24
14000
11000
16000
23000
7000
110
110
110
110
110
Vdc
624
591
527
470
*
Yellow
Green
Blue
5
5
5
Cool White
5
14000
mcd
mA
nm
fig 1
Please note that this product is also available in different voltages. Contact our sales department
for further details.
* = Typical emission colour: cool white x=0.31, y=0.32
Intensities (iv) and colour shades of white (x,y co-ordinates) may vary between LEDs within a
batch.
^ = Products must be derated when used above 45°C - Refer to fig 1.
Warm White LEDs may be used behind coloured lens as a true replacement for a filament lamp.
How to Order:
Max forward DC current vs ambient
temperature (Tjmax=105°C)
website: www.marl.co.uk
email: sales@marl.co.uk
Fax: +44 (0)1229 585155
webstore: www.leds.co.uk
•
•
Telephone +44 (0)1229 582430
•
•
The information contained in this datasheet does not constitute part of any order or contract and should not be regarded as a representation
relating to either products or service. Marl International reserve the right to alter without notice the specification or any conditions of supply
for products or service.
Page 1 of 2
© MARL INTERNATIONAL LTD 2006 : DS 060/06 Issue 1
SAMPLES AVAILABLE