MODEL: 20VS2-3
Overload input voltage: 30 V DC continuous
Hybrid IC Isolation Amplifiers 20 Series
Input offset voltage: ±15 mV
Input bias current: 15 nA TYP. (@25°C)
ISOLATION AMPLIFIER
(for narrow span, input isolation)
Functions & Features
OUTPUT SPECIFICATIONS
■ Voltage Output
• Being used for printed wiring board installation
• Isolating between input and output, input and power
• Built in surge protectors
Output range: 0 – 10 V DC
Load resistance: ≥ 2 kΩ
Output impedance: ≤ 1 Ω
• Isolation between input and output up to 2000 V AC
• Power 15 V DC
REFERENCE VOLTAGE SOURCE
Output voltage: ±11 V DC ±5 %
Load current: ≤ 5 mA
Typical Applications
• Isolating the field and iput circuit of microprocessor to
reduce noise from field
• Available for manufacturers of small-lot products to omit
the development of isolation circuit
INSTALLATION
Power input
•DC: Operational voltage range: Rating ±2 %; approx. 10
mA with no load; ripple 2 %p-p max.
Operating temperature: 0 to 60°C (32 to 140°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Soldering to the printed wiring board
Weight: 20 g (0.71 oz)
18 (.71)
14.5
(.57)
49 (1.93)
mm (inch)
PERFORMANCE in percentage of span
Linearity: ±0.05 %
MODEL: 20VS2–3–U
Temp. coefficient: Offset drift 40 ppm/°C
span drift 80 ppm/°C
ORDERING INFORMATION
Frequency characteristics:
• Code number: 20VS2-3-U
Approx. 2 Hz -3dB (narrow span input)
Approx. 1 kHz -3dB (not narrow span input)
Response time:
Narrow span input range: -10 – +100 mV DC
Input range: 0 – 5 V DC
≤ 200 ms (narrow span input)
Output range: 0 – 10 V DC
≤ 450 microseconds (not narrow span input)
Conversion gain: × 0.4 ±1 %
Line voltage effect: ±0.05 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @ 1 minute
(input or reference voltage source to output or power
supply)
POWER INPUT
DC Power
U: 15 V DC
GENERAL SPECIFICATIONS
Construction: Hybrid IC
STANDARDS & APPROVALS
EU conformity:
Housing material: Flame-resistant resin (black)
Isolation: Input or reference voltage source to output or
power supply
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
INPUT SPECIFICATIONS
■ Voltage Input
Narrow span input range: -10 – +100 mV DC
Input range: 0 – 5 V DC
Input resistance: ≥ 1 MΩ (10 kΩ in power failure)
20VS2-3 SPECIFICATIONS
ES-4408 Rev.5 Page 1/2
https://www.m-system.co.jp/