Features
Applications
nꢀ Telecommunicationsꢀequipment
nꢀ Industrialꢀequipment/electronics
nꢀ Size:ꢀ11.8ꢀmmꢀdiameter,ꢀꢀ
ꢀ
12ꢀmmꢀlength
nꢀ 60ꢀkAꢀsurgeꢀrating
nꢀꢀHighꢀpowerꢀhandling
nꢀꢀLowꢀleakage
nꢀ RoHSꢀcompliant*
nꢀ ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀULꢀRecognized
ꢀ
ꢀꢀ2061ꢀSeriesꢀHigh-Currentꢀ2-ElectrodeꢀGasꢀDischargeꢀTube
Characteristics
Test Methods per ITU-T K.12 and IEC 61643-311.
Model No.
2061-30
300 V
Characteristic
2061-23
2061-25
2061-35
2061-42
DC Sparkover ±20 % @ 100 V/s
230 V
250 V
350 V
420 V
Impulse Sparkover (1)
100 V/µs
1000 V/µs
< 600 V
< 700 V
< 600 V
< 700 V
< 700 V
< 800 V
< 800 V
< 900 V
< 900 V
< 1000 V
Model No.
Characteristic
2061-47
2061-60
2061-70
2061-80
DC Sparkover ±20 % @ 100 V/s
470 V
600 V
700 V
800 V
Impulse Sparkover (1)
100 V/µs
1000 V/µs
< 900 V
< 1100 V
< 1100 V
< 1300 V
< 1200 V
< 1400 V
< 1300 V
< 1500 V
(1)
Impulse Sparkover voltage is defined as typical values of distribution.
Insulation Resistance (IR) (2)....................................100 / 250 Vdc ........................................................ > 1 GW
Glow Voltage ...........................................................10 mA..................................................................... ~ 70 V
Arc Voltage..............................................................1 A.......................................................................... ~ 10 V
Glow-Arc Transition Current.................................................................................................................... < 1 A
Maximum Capacitance............................................1 MHz..................................................................... < 10 pF
Maximum Impulse Discharge Current .....................60,000 A, 8/20 µs .................................................. 1 operation
40,000 A, 8/20 µs ................................................... 5 operations
Nominal Alternating Discharge Current...................40 A, 50 Hz, 1 second............................................ 1 operation
200 A, 9 cycles ...................................................... 1 operation
Impulse Life ............................................................500 A, 10/1000 µs .................................................. > 400 operations
DC Holdover Voltage (3) ........................................................................................................................... < 150 ms
Operating Temperature............................................................................................................................ -30 to +85 ºC
Storage Temperature............................................................................................................................... -40 to +115 °C
Climatic Category (IEC 60068-1)............................................................................................................. 40 / 90 / 21
Notes:
• The 2061 Series is NOT intended for use as a surface mount component.
• UL Recognized component, UL File E313168.
• At delivery AQL 0.65, level II DIN ISO 2859
(2)
DC Sparkover Voltage
230–400 V
420–800 V
IR Measuring Voltage
100 V
250 V
(3)
Network Applied
DC Sparkover Voltage
230–250 V
DC Holdover Voltage
135 V
150 V
300–800 V
*RoHSꢀDirectiveꢀ2002/95/ECꢀJan.ꢀ27,ꢀ2003ꢀincludingꢀannexꢀandꢀRoHSꢀRecastꢀ2011/65/EUꢀJuneꢀ8,ꢀ2011.ꢀ
Specificationsꢀareꢀsubjectꢀtoꢀchangeꢀwithoutꢀnotice.
Theꢀdeviceꢀcharacteristicsꢀandꢀparametersꢀinꢀthisꢀdataꢀsheetꢀcanꢀandꢀdoꢀvaryꢀinꢀdifferentꢀapplicationsꢀandꢀactualꢀdeviceꢀperformanceꢀmayꢀvaryꢀoverꢀtime.