Features  
Applications  
Balanced Mini-TRIGARD™  
5 mm diameter, 7.5 mm long  
UL Recognized  
Telecommunications  
Industrial electronics  
Commercial electronics  
Consumer electronics  
Aircraft and military electronics  
RoHS compliant* versions available  
2036 Series - Miniature 3-Pole Gas Discharge Tube  
Characteristics  
Test Methods per ITU-T K.12, IEEE C62.31 and IEC 61643-311 GDT standards.  
Model No.  
Characteristic  
2036-07  
2036-09  
2036-15  
2036-20  
2036-23  
2036-25  
DC Sparkover ±20 % @ 100 V/s  
75 V  
90 V  
150 V  
200 V  
230 V  
250V  
Impulse Sparkover (1)  
100 V/μs  
1000 V/μs  
250 V  
525 V  
250 V  
550 V  
350 V  
500 V  
425 V  
575 V  
450 V  
600 V  
475 V  
625 V  
Model No.  
Characteristic  
2036-30  
2036-35  
2036-40  
2036-42  
2036-47  
2036-60  
DC Sparkover ±20 % @ 100 V/s  
300 V  
350 V  
400 V  
420 V  
470 V  
600 V  
Impulse Sparkover (1)  
100 V/μs  
1000 V/μs  
500 V  
650 V  
600 V  
750 V  
650 V  
825 V  
675 V  
850 V  
750 V  
950 V  
850 V  
1100 V  
(1)  
Impulse Sparkover voltage is defined as typical values of distribution.  
Impulse Transverse Delay..................1000 V/μs............................................................................... <75 ns  
Insulation Resistance .........................100 V (50 V for Model 2036–07 & 2036-09)........................... >1010  
Glow Voltage ......................................10 mA..................................................................................... ~70 V  
Arc Voltage.........................................1 A .......................................................................................... ~10 V  
Glow-Arc Transition Current............................................................................................................... <0.5 A  
Capacitance........................................1 MHz..................................................................................... <2 pF  
DC Holdover Voltage(2) .......................135 V, (52 V for Model 2036-07 & 2036-09,........................... <150 ms  
80 V for Model 2036-15)  
Ω
Impulse Discharge Current.................20000 A, 8/20 μs (3) ................................................................. 1 operation minimum  
10000 A, 8/20 μs .................................................................... >10 operations  
2000 A, 10/350 μs .................................................................. 1 operation  
200 A, 10/1000 μs ................................................................. >300 operations  
200 A, 10/700 μs ................................................................... >500 operations  
Alternating Discharge Current............20 Arms, 1 s (3) ........................................................................ 1 operation minimum  
10 Arms, 1 s ........................................................................... >10 operations  
Storage Temperature.......................................................................................................................... -55 to +105 °C  
Operating Temperature....................................................................................................................... -55 to +105 °C  
Climatic Category (IEC 60068-1)........................................................................................................ 55/105/21  
Moisture Sensitivity Level..................................................................................................................  
1
ESD Classification (HBM)..................................................................................................................  
6
An optional Switch-Grade Fail-Short device is available. The optional Fail-Short assembly will activate at a temperature of 215 °C – 217 °C  
to provide a high conductive path to ground in case of a thermal overload. GDTs equipped with the optional Fail-Short device should be  
soldered either manually at a temperature that is below the activation temperature of the Fail-Short mechanism, or using a selective soldering  
process that does not exceed 210 °C.  
Notes:  
UL recognized component, UL File E153537.  
No model number marking on tube; date code and voltage only: month year digits, xxxV (e.g. 0209 400V).  
The rated discharge current for Mini-TRIGARD™ Gas Discharge Tubes is the total current equally divided between each line to ground.  
Sparkover limits after life ±25 %, IR >108Ω (-25 %,+30 % for Model 2036-07, 2036-09 and 2036-60).  
Operating characteristics per RUS PE-80 and Telcordia GR 1361 available, contact factory.  
Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.  
At delivery AQL 0.65 Level II, DIN ISO 2859.  
(2) Network applied.  
(3) DC Sparkover may exceed ±25 % after discharge, but will continue to protect without venting.  
*RoHS Directive 2015/863, Mar 31, 2015 and Annex.  
Specifications are subject to change without notice. Users should verify actual device performance in their specific  
applications. The products described herein and this document are subject to specific legal disclaimers as set forth on the  
last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf.  
WARNING Cancer and Reproductive Harm  
www.P65Warnings.ca.gov  

与2036-60-B2F相关器件

型号 品牌 描述 获取价格 数据表
2036-60-B2-F BOURNS TELECOM, SURGE PROTECTION CIRCUIT, XSS3, PACKAGE-3

获取价格

2036-60-B2FFLF BOURNS Surge Protection Circuit,

获取价格

2036-60B2FLF BOURNS TELECOM, SURGE PROTECTION CIRCUIT, XSS3, ROHS COMPLIANT PACKAGE

获取价格

2036-60-B2FLF BOURNS Surge Protection Circuit, ROHS COMPLIANT PACKAGE-3

获取价格

2036-60-B2-FLF BOURNS TELECOM, SURGE PROTECTION CIRCUIT, XSS3, ROHS COMPLIANT, PACKAGE-3

获取价格

2036-60B2LF BOURNS TELECOM, SURGE PROTECTION CIRCUIT, XSS3, ROHS COMPLIANT PACKAGE

获取价格