2036-30-B2LF

更新时间: 2024-01-13 01:43:44
品牌 Logo 应用领域
伯恩斯 - BOURNS /
页数 文件大小 规格书
3页 426K
描述
Miniature 3-Pole Gas Discharge Tube

2036-30-B2LF 数据手册

 浏览型号2036-30-B2LF的Datasheet PDF文件第2页浏览型号2036-30-B2LF的Datasheet PDF文件第3页 
Features  
Applications  
nꢀ BalancedꢀMini-TRIGARD™ꢀ  
nꢀ 5ꢀmmꢀdiameter,ꢀ7.5ꢀmmꢀlongꢀ  
nꢀ ULꢀRecognized  
nꢀ Telecommunications  
nꢀ Industrialꢀelectronics  
nꢀ Commercialꢀelectronics  
nꢀ Consumerꢀelectronics  
nꢀ Automotive,ꢀaircraft,ꢀmilitaryꢀelectronics  
nꢀ RoHSꢀcompliant*ꢀversionsꢀavailable  
ꢀ2036ꢀSeriesꢀ-ꢀMiniatureꢀ3-PoleꢀGasꢀDischargeꢀTube  
Characteristics  
Test Methods per ITU-T K.12, IEEE C62.31 and IEC 61643-311 GDT standards.  
Model No.  
Characteristic  
2036-07  
2036-09  
2036-15  
2036-20  
2036-23  
2036-25  
DC Sparkover ±20 % @ 100 V/s  
75 V  
90 V  
150 V  
200 V  
230 V  
250V  
Impulse Sparkover (1)  
100 V/µs  
1000 V/µs  
250 V  
525 V  
250 V  
550 V  
350 V  
500 V  
425 V  
575 V  
450 V  
600 V  
475 V  
625 V  
Model No.  
Characteristic  
2036-30  
2036-35  
2036-40  
2036-42  
2036-47  
2036-60  
DC Sparkover ±20 % @ 100 V/s  
300 V  
350 V  
400 V  
420 V  
470 V  
600 V  
Impulse Sparkover (1)  
100 V/µs  
1000 V/µs  
500 V  
650 V  
600 V  
750 V  
650 V  
825 V  
675 V  
850 V  
750 V  
950 V  
850 V  
1100 V  
(1)  
Impulse Sparkover voltage is defined as typical values of distribution.  
Impulse Transverse Delay..................1000 V/µs............................................................................... <75 ns  
Insulation Resistance .........................100 V (50 V for Model 2036–07 & 2036-09)........................... >1010  
Glow Voltage ......................................10 mA..................................................................................... ~70 V  
Arc Voltage.........................................1 A .......................................................................................... ~10 V  
Glow-Arc Transition Current............................................................................................................... <0.5 A  
Capacitance........................................1 MHz..................................................................................... <2 pF  
DC Holdover Voltage(2) .......................135 V, (52 V for Model 2036-07 & 2036-09,........................... <150 ms  
80 V for Model 2036-15)  
Ω
Impulse Discharge Current.................20000 A, 8/20 µs (3) ................................................................. 1 operation minimum  
10000 A, 8/20 µs .................................................................... >10 operations  
2000 A, 10/350 µs .................................................................. 1 operation  
200 A, 10/1000 µs ................................................................. >300 operations  
200 A, 10/700 µs ................................................................... >500 operations  
Alternating Discharge Current............20 Arms, 1 s (3) ........................................................................ 1 operation minimum  
10 Arms, 1 s ........................................................................... >10 operations  
Storage Temperature.......................................................................................................................... -55 to +105 °C  
Operating Temperature....................................................................................................................... -55 to +105 °C  
Climatic Category (IEC 60068-1)........................................................................................................ 55/105/21  
An optional Switch-Grade Fail-Short device is available. The optional Fail-Short assembly will activate at a temperature of 215 °C – 217 °C  
to provide a high conductive path to ground in case of a thermal overload. GDTs equipped with the optional Fail-Short device should be  
soldered either manually at a temperature that is below the activation temperature of the Fail-Short mechanism, or using a selective soldering  
process that does not exceed 210 °C.  
Notes:  
UL recognized component, UL File E153537.  
No model number marking on tube; date code and voltage only: month year digits, xxxV (e.g. 0209 400V).  
The rated discharge current for Mini-TRIGARD™ Gas Discharge Tubes is the total current equally divided between each line to ground.  
Sparkover limits after life ±25 %, IR >108Ω (-25 %,+30 % for Model 2036-07, 2036-09 and 2036-60).  
Operating characteristics per RUS PE-80 and Telcordia GR 1361 available, contact factory.  
Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.  
At delivery AQL 0.65 Level II, DIN ISO 2859.  
(2) Network applied.  
(3) DC Sparkover may exceed ±25 % after discharge, but will continue to protect without venting.  
*RoHSꢀDirectiveꢀ2002/95/ECꢀJan.ꢀ27,ꢀ2003ꢀincludingꢀannexꢀandꢀRoHSꢀRecastꢀ2011/65/EUꢀJuneꢀ8,ꢀ2011.ꢀ  
Specificationsꢀareꢀsubjectꢀtoꢀchangeꢀwithoutꢀnotice.  
Theꢀdeviceꢀcharacteristicsꢀandꢀparametersꢀinꢀthisꢀdataꢀsheetꢀcanꢀandꢀdoꢀvaryꢀinꢀdifferentꢀapplicationsꢀandꢀactualꢀdeviceꢀperformanceꢀmayꢀvaryꢀoverꢀtime.  
Usersꢀshouldꢀverifyꢀactualꢀdeviceꢀperformanceꢀinꢀtheirꢀspecificꢀapplications.  

与2036-30-B2LF相关器件

型号 品牌 描述 获取价格 数据表
2036-30B3 BOURNS TELECOM, SURGE PROTECTION CIRCUIT, XSS3

获取价格

2036-30-B3 BOURNS Surge Protection Circuit, PACKAGE-3

获取价格

2036-30B3F BOURNS Surge Protection Circuit,

获取价格

2036-30-B3F BOURNS TELECOM, SURGE PROTECTION CIRCUIT, XSS3, PACKAGE-3

获取价格

2036-30B3FLF BOURNS Surge Protection Circuit, ROHS COMPLIANT PACKAGE

获取价格

2036-30-B3FLF BOURNS Surge Protection Circuit, ROHS COMPLIANT PACKAGE

获取价格