General Purpose Relays
Power Relays
Potter & Brumfield
Power PCB Relay T9S Solar
n
n
n
n
n
n
n
1 pole 35A, 1 form A (NO) contact
Contact gap >1.5mm (standard), >1.8mm (suffix S)
350mW hold power
Ambient temperature up to 85°C at 35A
The appliance is able to meet VDE V 0126-1-1
Product in accordance to IEC 60335-1
EN61095: AC7a at 85°C
Typical applications
Photovoltaic inverter
f0156_bc_inv
U
Approvals
Insulation Data
VDE 40030974, UL E58304
Technical data of approved types on request
Initial dielectric strength
between open contacts
between contact and coil
Clearance/creepage
2500Vrms
4000Vrms
Contact Data
Contact arrangement
Contact gap
Rated voltage
Rated current
Breaking capacity max.
Contact material
Initial contact resistance
Frequency of operation, with/without load
Operate/release time max., incl bounce time
1 form A (NO)
between contact and coil
Material group of insulation parts
Tracking index of relay base
3/4mm
III
PTI 325
>1.5mm (standard), >1.8mm (suffix S)
250VAC (1.8mm gap), 277VAC (1.5mm gap)
35A1)
8750 VA
AgNi
Other Data
75mΩ max. at 1A 6VDC
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
6/300min-1
18/15ms
www.te.com/customersupport/rohssupportcenter
Ambient temperature
Category of environmental protection
IEC 61810
Vibration resistance (functional)
Shock resistance (functional)
Shock resistance (destructive)
Terminal type
Mounting
Mounting distance
Weight
Resistance to soldering heat THT
IEC 60068-2-20
Packaging unit
1) The relay connections and wiring have to be designed with an adequate cross sections
to ensure the current flow and heat dissipation.
-40 to +85°C1)
Contact ratings2)
Type
IEC 61810
T9SV1K15-12
T9SV1K15-12S A (NO)
UL 508
T9SV1K15-12
T9SV1K15-12S A (NO)
Contact
Load
Cycles
RTII - flux proof
10g
A (NO)
35A, 250VAC, cosφ=1, 85°C
35A, 250VAC, cosφ=1, 85°C
30x103
20x103
10g
100g
PCB-THT
see note1)
≥10mm
appr. 30g
A (NO)
35A, 277VAC, resistive, 85°C
35A, 250VAC, resistive, 85°C
30x103
20x103
Mechanical endurance, DC coil
1) The relay connections and wiring have to be designed with an adequate cross sections
to ensure the current flow and heat dissipation.
1x106 operations
260°C/5s
box/500 pcs.
2) Contact ratings with relay properly verted.
Coil Data
Rated coil voltage
12VDC
class F
Coil insulation system according UL
Coil versions, DC coil
Coil
code
Rated
voltage
VDC
Operate
voltage
VDC
Release
voltage
VDC
Coil
Rated coil
power
W
2.25 /
min. 0.35
hold
resistance
Ω 10ꢀ
64+10ꢀ
12
122)
9.6
0.8
2) After the energization time of 100 ms with 12 VDC the coil requires a reduction of the coil
voltage to 4.7...6.0 VDC.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
1
09-2016, Rev. 0916
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company