更新时间: 2024-02-07 22:15:03
品牌 Logo 应用领域
伯恩斯 - BOURNS 电信电信集成电路
页数 文件大小 规格书
3页 257K
描述
3-Pole Gas Discharge Tubes Sparkover100V/s 350V 3 Pole

2026-35-C4 技术参数

是否Rohs认证: 符合生命周期:Active
包装说明:,Reach Compliance Code:compliant
Factory Lead Time:5 weeks风险等级:5.8
JESD-30 代码:O-XXSS-P3JESD-609代码:e3
湿度敏感等级:1功能数量:1
端子数量:3最高工作温度:90 °C
最低工作温度:-40 °C封装主体材料:UNSPECIFIED
封装形状:ROUND封装形式:SPECIAL SHAPE
峰值回流温度(摄氏度):NOT SPECIFIED认证状态:Not Qualified
表面贴装:NO电信集成电路类型:SURGE PROTECTION CIRCUIT
温度等级:INDUSTRIAL端子面层:Tin (Sn)
端子形式:PIN/PEG端子位置:UNSPECIFIED
处于峰值回流温度下的最长时间:NOT SPECIFIEDBase Number Matches:1

2026-35-C4 数据手册

 浏览型号2026-35-C4的Datasheet PDF文件第2页浏览型号2026-35-C4的Datasheet PDF文件第3页 
Features  
Applications  
Telecommunications  
Balanced TRIGARD®  
Approximately 8 mm diameter, 11 mm long  
UL recognized  
Custom configurations available  
High surge current rating  
Stable breakdown throughout life  
RoHS compliant* version available  
Industrial electronics  
Commercial electronics  
Consumer electronics  
Automotive, aircraft, military electronics  
2026 Series - 3-Pole Gas Discharge Tube  
Characteristics  
Test Methods per ITU-T (CCITT) K.12, IEEE C62.31, RUS PE-80, Telcordia GR 1361  
Model No.  
Characteristic  
2026-07  
2026-09  
2026-15  
2026-20  
2026-23  
2026-25  
2026-26  
260V1  
DC Sparkover 20 ꢀ ꢁ 100 V/s  
75 V  
90 V  
150 V  
200 V  
230 V  
250 V  
Impulse Sparkover  
100 V/µs  
1000 V/µs  
275 V  
700 V  
275 V  
600 V  
350 V  
575 V  
425 V  
625 V  
450 V  
650 V  
475 V  
700 V  
475 V  
700 V  
Model No.  
Characteristic  
2026-30  
2026-35  
2026-40  
2026-42  
2026-47  
2026-60  
DC Sparkover 20 ꢀ ꢁ 100 V/s  
300 V  
350 V  
400 V  
420 V  
470 V  
600 V  
Impulse Sparkover  
100 V/µs  
1000 V/µs  
500 V  
775 V  
625 V  
875 V  
675 V  
925 V  
725 V  
1000 V  
800 V  
1100 V  
925 V  
1250 V  
Impulse Transverse Delay......................................1000 V/µs.....................................................................< 75 ns  
Insulation Resistance.............................................100 V (50 V for Model 2026–07 & 2026-09).................> 1010 Ω  
Glow Voltage..........................................................10 mA...........................................................................~ 70 V  
Arc Voltage.............................................................1A.................................................................................~ 10 V  
Glow-Arc Transition Current........................................................................................................................< 0.5 A  
Capacitance...........................................................1 MHz...........................................................................< 2 pF  
DC Holdover Voltage2 ...........................................>135 V, (52 V for Model 2026-07 & 2026-09,...............< 150 ms  
80 V for Model 2026-15)  
Impulse Discharge Current ....................................40000 A, 8/20 µs3......................................................... 1 operation minimum  
20000 A, 8/20 µs..........................................................> 10 operations  
1000 A, 10/1000 µs .....................................................> 400 operations  
Alternating Discharge Current................................130 Arms, 11 cycles3 ................................................... 1 operation minimum  
20 Arms, 1 s.................................................................> 10 operations  
Operation and Storage Temperature, Climatic Category (IEC 60068-1) 40/ 90/ 21.................................... -40 to +90 °C  
Optional Switch-Grade Fail-short device available.  
Notes:  
UL recognized component, UL File E153537.  
• Model number marking on tube: 26-xxx V.  
• The rated discharge current for TRIGARD¤ Gas Discharge Tubes is the total current equally divided between each line to ground.  
• Sparkover limits after life 25 ꢀ, IR >108(-25 ꢀ,+30 ꢀ for Model 2026-07, 2026-09 and 2026-60).  
• Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.  
• At delivery AQL 0.65 Level II, DIN ISO 2859  
1 Tube meets BT requirement Type 14 A/1 (210-310 V).  
2 Network applied.  
3 DC Sparkover may exceed 25 ꢀ after discharge, but will continue to protect without venting.  
*RoHS Directive 2002/95/EC Jan 27 2003 including Annex  
Specifications are subject to change without notice.  
Customers should verify actual device performance in their specific applications.  

与2026-35-C4相关器件

型号 品牌 描述 获取价格 数据表
2026-35-C4F BOURNS GAS DISCHARGE TUBE

获取价格

2026-35-C4FLF BOURNS GAS DISCHARGE TUBE

获取价格

2026-35C4LF BOURNS Surge Protection Circuit, ROHS COMPLIANT PACKAGE

获取价格

2026-35-C4LF BOURNS 暂无描述

获取价格

2026-35C8F BOURNS Surge Protection Circuit,

获取价格

2026-35C8FLF BOURNS Surge Protection Circuit, ROHS COMPLIANT PACKAGE

获取价格