200ACP_SCF Series
200W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
AC-DC Converter
200 Watt
High efficiency up to 87%
Universal AC input range
(85~264VAC)
Wide operating ambient
temperature (-20°C~65°C)
Operating altitude
The 200ACP_SCF series features standard rail mounting, energy effici-
ency and is highly cost-effective. The series offers stability and high
noise immunity especially for industrial control equipment, machinery
and other demanding environments for industrial equipment. This con-
verter offers a compact and light weight design with and standard rail
installation (35mm). Furthermore this series offers Easy Fuse Tripping
due and a built-in DC OK relay contact. The converter can be installed
on TS-35/7.5 or TS-35/15.
Built-in Active PFC function,
PF>0.95
up to 5000M
100% full load burn-in test
Withstand 300Vac surge
input for 5s
PCB soldering side with
conformal coating
Over power protection (OPP)
Over load protection (OLP)
Short circuit protection (SCP)
UL-60950-1 (E347551)
Common specifications
Short circut protection:
Temperature rise at full load:
Cooling:
Input specifications
Long-term mode, automatic recovery
40°C MAX
Input voltage range
Input frequency
Power factor
90~264VAC, 120Vdc~370Vdc
47~63Hz
115VAC
• 0.98 (typ)
230VAC
• 0.95 (typ)
Free air convection
-20°C~+65°C
Operation temperature range:
Storage temperature range:
Storage humidity range:
Temperature coefficient:
MTBF (using MIL-HDBK-217F):
Power boost:
AC current
3.5A (max)
-40°C ~+85°C
Inrush current
Cold start
115VAC
• 30A (typ)
220VAC
• 50A (typ)
< 95%
0.03%/°C MAX
Leakage current
Input—output: ≤0.25mA
Input—PG: ≤3.5mA
+25°C >200,000 hours
150% of rated current
support
Parallel function:
Output specifications
Safety standards:
UL60950-1 2nd Ed; IEC 60950-1:2005(2nd
Ed); EN60950-1:2006
Item
Test conditions
Min Typ
Max
Units
Output voltage
accuracy
Full load
• 12V
• 24V/36V/48V
Case material:
Heat-resistant Plastic (UL94-V0) and
metal
2
1
%
%
Dimensions:
Weight:
199*99*50mm
950g
Voltage adjustment • 12V
9
15
V
V
V
V
range
• 24V
• 36V
• 48V
20
32
40
27
40
53
Line regulation
Load regulation
Vin= min. to max. at
full load
0.5
%
Isolation specifications
Item
Test condition
Min
Typ
Max
Units
VAC
0% to 100% load
• 12V
• 24V/36V/48V
Withstand voltage*
• Primary-Sec.: 10mA
• Primary-PG: 10mA
• Secondary-PG
3000
1500
500
2
1
%
%
Set-up time
• @230VAC input
• @115VAC input
2
4
s
s
Isolation resistance
10
MΩ
Hold-up time
@full load
12
ms
%
* Input-Output, tested for 1 minute, 500VDC and leakage current less than 1mA
Overshoot and
undershoot
5
Protection specifications
Switching fre-
quency
100
KHz
Over-load
protection
• 12V: 18~30A
• 24V: 10~15A
• 36V: 5.88~8.8A
• 48V: 5~7.56A
Protection type:
Hiccup mode, auto recovery
* Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated
Example:
Over-power
protection
• 12V: 216~360W
• 24V: 240~360W
• 36V: 210~320W
• 48V: 240~363W
Protection type:
200ACP_24SCF
Hiccup mode, auto recovery
200 = 200Watt
AC = AC-DC
P = series
24 = 24 Vout
S = Single Output
C = PFC (Power Factor Correction)
F = Fan
Note:
1. All parameters NOT specially mentioned are measured at rated input, rated
load and 25°C of ambient temperature.
Page 1 of 3
200ACP_SCF – Rev. 2020-1.1
Specifications subject to change without notice.
GAPTEC-Electronic GmbH & Co. KG
sales@gaptec-electronic.com – www.gaptec-electronic.com