Features
■ Heavy duty design
■ High frequency DC-4 GHz
■ DC Pass to 4ꢀ ꢁ
■ ꢁSWR <1.2
■ Replaceable gas tube
■ Three grounding options
■ RoHS compliant*
■
Listed (File: E360007)
■ Low insertion loss <0.1 dB
■ Bidirectional
■ Water resistant
1977 Series High Frequency Coaxial SPD
General Information
®
The Bourns Model 1977 Series Coaxial Surge Protective Device (SPD) has been designed to provide heavy duty protection for
antennas, broadband, microwave, GPS, cellular and CATV applications against surges caused by lightning and other electrical
transients.
Electrical Characteristics
Model No.
Characteristic
1977-09-xxx
1977-25-xxx
DC-4 GHz
200-300 V
Gas Discharge Tube
≤0.2 db
1977-50-xxx
Frequency Range
DC Turn-On (Breakdown)
Technology
90-130 V
400-600 V
Insertion Loss
Return Loss
≥20 db
VSWR
<1.2:1
Ipeak (8/20 μs)
Maximum Power
Maximum Current
Impedance
20 kA
25 W
190 W
780 W
10 A
1
50 ohms
1
Impedance for F-Type Connector is 75 ohms.
General Characteristics
Characteristic
Model No.
1977-25-xxx
1977-09-xxx
1977-50-xxx
Connection Method
Connectors
Grounding
Series (Bidirectional)
N, F
M6 Screw, Bulkhead, Bracket
4.4 oz.
Weight
Environmental Characteristics
Characteristic
Environmental Rating
Operating Temperature
Operating Altitude
Model No.
1977-25-xxx
1977-09-xxx
1977-50-xxx
IP 65
-50 °C to +85 °C
13,000 ft. (4,000 m)
Up to 5-95 %
Relative Humidity
Non-condensing: Up to 100 %
Asia-Pacific: Tel: +886-2 2562-4117 • Fax: +886-2 2562-4116
Europe: Tel: +41-41 768 5555 • Fax: +41-41 768 5510
The Americas: Tel: +1-951 781-5500 • Fax: +1-951 781-5700
www.bourns.com
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June ꢀ, 2011.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.