5秒后页面跳转
194L-G3515F PDF预览

194L-G3515F

更新时间: 2024-11-26 05:56:43
品牌 Logo 应用领域
罗克韦尔 - ALLEN-BRADLEY /
页数 文件大小 规格书
12页 196K
描述
Bulletin 194E

194L-G3515F 数据手册

 浏览型号194L-G3515F的Datasheet PDF文件第2页浏览型号194L-G3515F的Datasheet PDF文件第3页浏览型号194L-G3515F的Datasheet PDF文件第4页浏览型号194L-G3515F的Datasheet PDF文件第5页浏览型号194L-G3515F的Datasheet PDF文件第6页浏览型号194L-G3515F的Datasheet PDF文件第7页 
IEC Load Switches  
Bulletin 194E  
125 Amps to 315 Amps  
Features  
At-Motor Disconnect Switch  
125, 160, 250, 315 A Versions of Inductive Load-Rated Switches  
IP65/Type 1/3/3R/12 Operating Handles  
IP2LX Finger-Safe Terminals  
3- and 4-Pole Versions  
Front/Door or DIN/Base Mounting Configurations  
OFF-ON Configurations  
Box Lug and Bolt-on Terminals Available  
Switches Include Operating Shaft  
Suitable as Motor Disconnect  
Conform ity to Standards  
IEC 207  
IEC 947-1  
IEC 947-3 low-voltage switchgear and control gear part 3:  
switches, disconnecters, switch-disconnecters and fuse-  
combination units. CE  
Description  
UL 508: Industrial Control Equipment. CUL  
Bulletin 194E load switches are designed for use in North America  
as local motor isolation and for IEC disconnect switch applications  
outside of North America. Available in 3- and 4-pole versions with  
add-on grounding and neutral terminals and auxiliary contacts,  
Bulletin 194Es use similar operating handles as the Bulletin 194L  
Control and Load Switches.  
Approvals  
UL listed (Box Lug Version)  
UR recognized (Bolt-on Version)  
CUL listed (Box Lug Version)  
CUR recognized (Bolt-on Version)  
Meets IEC, VDE and BS standard requirements  
IEC/CE marked for all applicable directives (per EN 60947-3)  
Bulletin 194E switches are offered in two mounting styles, Front/  
Door and Base/DIN configurations, for a variety of installations.  
Switch body styles for Bulletin 194E base-mounted switches include  
standard interlock shaft; Bulletin 194E front-mounted switches  
include standard shaft.  
Your order m ust include:  
Catalogue Number of switch body.  
Catalogue Number of actuator.  
If required, Catalogue Number of accessories.  
Two-position OFF-ON switch is used to connect or disconnect a  
variety of inductive loads, including solenoids, actuators, valves,  
magnetic starters, relays, and motors up to 100 HP.  
10-25