Multiple Case Sizes - High Voltage – High Current
Filtering – Switching Power Supplies
FEATURES
APPLICATIONS
-40°C to +85°C (10VDC to 250VDC)
-25°C to +85°C (350VDC to 500VDC)
+20% at 120 Hz, 20°C
Operating Temperature
Range
Capacitance Tolerance
10
13
10
.55
16
20
16
.5
25
32
25
.45
35
44
35
.4
50
63
50
.35
63
80
100
120
100
.2
160
200
160
.15
200
250
200
.15
250
300
250
.15
350
400
350
.15
400 450
450 500
400 450
500
550
500
.2
WVDC
Surge Voltage
SVDC
79 100
63
80
WVDC
Dissipation
Factor
tan δ
.3
.25
.15
.2
For capacitance values above 33000μF
add the following to the Dissipation factors values above
(capacitance-33000 μF)*0.1
10000 μF
(120 Hz)
Leakage Current
@20°C, Rated WVDC
applied
5 Minutes
3√CV
Time
10
16
25
35
50
63
80 100 160 200
250
350
400
450
500
WVDC
-25°C/+20°C
Impedance
4
4
4
4
4
4
4
4
3
3
3
3
8
8
8
Ratio
(120 Hz)
-40°C/+20°C
15
15
15
15
15
15
15
15
15
15
15
-
-
-
-
2000 hours with rated voltage applied at 85°C with full rated ripple current applied
Capacitance Change
Dissipation Factor
Leakage Current
<20% of initial measured value
Load Life
<200% of maximum specified value
<100% of maximum specified value
1000 hours at 85°C with no voltage applied
<20% of initial measured value
Capacitance Change
Dissipation Factor
Leakage Current
Shelf Life
<200% of maximum specified value
<100% of maximum specified value
Frequency (Hz)
WVDC
60
120
1k
10k
Ripple Current
Multipliers
10 to 100
160 to 250
350 to 500
0.9
0.8
0.8
1.0
1.0
1.0
1.15
1.15
1.15
1.25
1.47
1.47
.
Feb-17