180ACMOP_S4 Series
180W - Open Frame Type Switching Power Supply - Universal Input - Isolated & Regulated
AC-DC Converter
180 Watt
Universal input: 90~264VAC
High efficiency: >87% typical
Short circuit protection (SCP)
Over load protection (OLP)
Over voltage protection (OVP)
No load power consumption
Compact, high power density
Medical 60601-1 3rd Edition
MOPP and ITE approved
Meet DOE level VI & ErP Tier 1
requirements
The 180ACMOP_S4 series is a compact size power converter offered by
Gaptec. It features universal input voltage, taking AC input voltage, low
power consumption, high efficiency, high reliability, safer isolation. It
offers good EMC performance, meets IEC/EN61000-4, CISPR22/EN55022,
UL60950 and EN60950 standards, and is widely used in medical instru-
mentation and critical applications in commercial and industrial elect-
ronic equipment.
UL 60950-1
(pending)
Approval
Model
Power
[W]
Output
voltage[V]
Load convection
[A, max]
15CFM forced air
[A, max]
Ripple&Noise
[mV, Vp-p]
Output
Regulation [%]
Efficiency
[@115VAC, %, typ]
UL/CE
UL/CE
UL/CE
UL/CE
UL/CE
UL/CE
180ACMOP_12S4
180ACMOP_15S4
180ACMOP_19S4
180ACMOP_24S4
180ACMOP_28S4
180ACMOP_48S4
180
180
180
180
180
180
12
15
10
8
15
12
240
240
240
240
240
240
±±
±±
±2
±2
±2
±2
>87
>87
>87
>87
>87
>87
19
24
28
48
6.±2
5
9.48
7.5
4.29
2.5
6.4±
±.75
Input specifications
Input voltage range
Input frequency
Power factor
Output specifications
Item
90-264 VAC
Test conditions
Min Typ
Max
180
Units
W
47~6±Hz
Output power
with 15CFM forced air
cooling
115VAC
• 0.95A (max)
2±0VAC
• 0.9A (max)
Output voltage
accuracy
Full load
±2
20
%
Input current
115VAC
• ±A (max)
2±0VAC
• 1.5A (max)
Hold-up time
@load 75%, 115VAC
ms
Inrush current
(cold start @25°C)
115VAC
• 50A (typ)
2±0VAC
• 100A (typ)
Example:
Leakage current
< 100µA/264VAC
• 2A
180ACMOP_05S4
180= 180Watt; AC= AC-DC; MOP= series; 5Vout; S= Single Output;
4= 4kVAC
Recommended external
fuse
• High Breaking
capacity
Note:
Protection specifications
1. This product is not designed for use in critical life support systems, equipment
used in hazardous environment, nuclear control systems or other such
applications which necessitate specific safety and regulatory standards other
the ones listed in this datasheet.
2. At 25°C including initial tolerance, line voltage, load currents and output volta-
ges adjusted to factory settings.
Short circuit
protection
Protection type:
Auto-recovery
Over-voltage
protection
Protection type:
Latching type. AC Recycle
±. Ripple and noise are measured at oscilloscope 20MHz bandwidth by a 10uF
electrolytic capacitor and a 0.1uF ceramic capacitor in parallel at output
connector.
Over-load
protection
Protection type:
110% to 150% maximum rating, Auto-recovery