ISO-ANALYTICAL  
Laboratory Report  
Client:  
Your Company  
Contact(s): Your Name  
Analysis:  
δ2H (deuterium) and δ18O of Doubly Labeled Water (DLW)  
IA Ref. No.: Our LIMS Code  
Your Ref.: Your Job Code  
From:  
Date:  
Steve Brookes  
April 20, 2007  
We have completed the deuterium and oxygen-18 analysis of the urine and  
dose samples that we received on April 2, 2007. The results of analysis can  
be found attachment as an MS Excel worksheet.  
The samples were measured in duplicate with results being presented in both  
per mil (‰) and parts per million (ppm) notation. The analysis proceeded as  
follows:  
Deuterium  
A sample size of 0.3 mL was pipetted into septum sealed vials and insert vials  
containing 5 % platinum on alumina catalyst added. The vials were sealed  
and the headspace flushed with pure H2 gas. References and quality control  
check samples were prepared in the same manner. Once all vials were  
flushed they were left to equilibrate for a period of three days to ensure  
complete equilibration. The samples and references were subsequently  
analysed by Continuous Flow - Isotope Ratio Mass Spectrometry (CF-IRMS)  
using a Europa Scientific ANCA-GSL and GEO 20-20 IRMS.  
Samples were calibrated against two laboratory reference waters IA-R018  
(δ2HV-SMOW = -56.5 ‰) and IA-R020 (δ2HV-SMOW = 1089.2 ‰). Accuracy was  
checked by measuring laboratory standard water IA-R019 (δ2HV-SMOW = 522.3  
‰) as a check sample within each batch of samples. Data for the check  
samples is reported in the results table.  
Oxygen-18  
Following deuterium analysis, vials were flushed with pure CO2 gas and left to  
equilibrate for 24 hours. Reference waters and quality control check samples  
were prepared in the same manner. The samples and references were  
subsequently analysed by CF-IRMS using a Europa Scientific ANCA-G and  
Hydra 20-20 IRMS.  
1

与160-2085-02-01-00相关器件

型号 品牌 获取价格 描述 数据表
160-2085-02-04-00 CAMBION

获取价格

PCB Terminal
160-2085-03-01-00 CAMBION

获取价格

PCB Terminal
160-2085-11-03-00 CAMBION

获取价格

PCB Terminal
160-2085-11-04-00 CAMBION

获取价格

PCB Terminal
1602087 PHOENIX

获取价格

Circular Connector,
1602097 PHOENIX

获取价格

Circular Connector
1602099 PHOENIX

获取价格

Circular Connector,
16021 COOPER

获取价格

Power Distribution & Terminal Blocks
160210 OSA

获取价格

GaP / GaP LED Chips
160-2100 CAMBION

获取价格

Solder terminal, turreted, thru hole