138D
Vishay
www.vishay.com
®
Wet Tantalum Capacitors Silver Case TANTALEX Capacitors
Hermetically-Sealed
FEATURES
• Terminations: Axial, standard tin/lead (SnPb),
100 % tin (RoHS-compliant) available
• Model 138D is the commercial equivalents of
Tansitor styles WT, UWT, Mallory-NACC styles
TLX, TXX and Military styles CL66, CL67, CLR65, and
CLR69, designed to meet the performance requirements
of
Military
Specification
MIL-PRF-39006/09/21.
Capacitors in accordance with military specifications
should be ordered by their military part numbers.
• Mounting: Through-hole
• Material categorization: For definitions of compliance
please see www.vishay.com/doc?99912
Note
* Lead (Pb)-containing terminations are not RoHS-compliant.
Exemptions may apply.
PERFORMANCE CHARACTERISTICS
Operating Temperature: - 55 °C to + 85 °C (to + 125 °C
1. DCL shall not exceed 125 % of the original requirement.
with voltage derating)
2. The ESR shall not exceed 200 % of the initial
requirement.
Capacitance Tolerance: At 120 Hz, + 25 °C.
standard. 10 %, 5 % available as special.
20 %
3. Change in capacitance value shall not exceed the
percentages below.
DC Leakage Current (DCL Max.): At + 25 °C, + 85 °C and
+ 125 °C: Leakage current shall not exceed the values listed
in the Standard Ratings tables.
a) 6 VDC units: + 10 % to - 25 % of initial measurement.
b) 8 VDC and 10 VDC units: + 10 % to - 20 % of initial
measurement.
Life Test: Capacitors are capable of withstanding a 2000 h
life test at a temperature of + 85 °C or + 125 °C at the
applicable rated DC working voltage.
c) 15 VDC units: + 10 % to - 15 % of initial measurement.
d) 20 VDC and above: 10 % of initial measurement.
Following the life test:
ORDERING INFORMATION
138D
306
X0
006
C
2
E3
MODEL
CAPACITANCE
CAPACITANCE
TOLERANCE
DC VOLTAGE RATING
AT + 85 °C
CASE
CODE
TERMINATION
RoHS COMPLIANT
This is expressed
in picofarads. The
first two digits are
the significant
figures. The third is
the number of
X0 = 20 %
X9 = 10 %
X5 = 5 %
special order
This is expressed in volts.
To complete the
three-digit block, zeros
precede the voltage
rating. A decimal point is
indicated by an “R”
(6R3 = 6.3 V)
See
Ratings
and Case
Codes
table
0 = No outer sleeve
2 = Outer plastic film
insulation
E3 = 100 % tin
termination
(RoHS compliant)
Blank = SnPb
termination
(standard design)
zeros to follow
Note
•
Packaging: The use of formed plastic trays for packaging these axial lead components is standard. Tape and reel is not available due to the
unit weight.
Revision: 21-Mar-13
Document Number: 40025
1
For technical questions, contact: tantalum@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000