MODEL: 10JPA
High-density Signal Conditioners 10-RACK
[1] INPUT
1: Open collector (Excitation: 12 V @ 30 mA)
2: Voltage pulse (Excitation: 12 V @ 30 mA)
3: Mechanical contact (Excitation: 12 V @ 30 mA)
FREQUENCY TRANSMITTER
(field-programmable)
Functions & Features
• Converting the output from a pulse-type transducer into
two standard process signals
[2] OUTPUT 1
Current
• Microprocessor based
A: 4 – 20 mA DC (Load resistance 600 Ω max.)
Voltage
• Field-programmable frequency range
• Linearization available for flow compensation
• Averaging non-uniform pulses
6: 1 – 5 V DC (Load resistance 500 Ω min.)
• Excitation
[3] OUTPUT 2
0: None
• Loop testing via hand-held programmer PU-2x
• Optional second channel output available at the front
terminals and at the Standard Rack connector
Voltage
6: 1 – 5 V DC (Load resistance 5000 Ω min.)
Typical Applications
POWER INPUT
DC Power
• Positive displacement flowmeters, turbine flowmeters and
vortex flowmeters
R: 24 V DC
• Proximity switches
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
• Oval flowmeters
[4] OPTIONS
blank: none
/Q: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating
RELATED PRODUCTS
• Programming Unit (model: PU-2x)
MODEL: 10JPA–[1][2][3]–R[4]
• PC configurator software (model: JXCON)
Downloadable at M-System’s web site.
A dedicated cable is required to connect the module to the
PC. Please refer to the internet software download site or
the users manual for the PC configurator for applicable
cable types.
ORDERING INFORMATION
• Code number: 10JPA-[1][2][3]-R[4]
Specify a code from below for each [1] through [4].
(e.g. 10JPA-2A6-R/Q)
• Frequency range (e.g. 0 – 152.3 Hz)
• Linearization data (max. 16 points)
Use Ordering Information Sheet (No. ESU-1673) to specify
linearization data when the I/O signals are non-linear.
• Specify the specification for option code /Q
(e.g. /C01)
GENERAL SPECIFICATIONS
Construction: Rack-mounted; terminal access via screw
terminals at the front and via card-edge connector at the
rear; terminal cover provided
Connection
Note: Consult factory on applications with a sensor handling
periodically (& quickly) changing frequency (e.g. oval
flowmeter).
Input: M3.5 screw terminals (torque 0.8 N·m)
Output: Card-edge connector and M3.5 screw terminals
(torque 0.8 N·m)
Power input: Supplied from card-edge connector
http://www.m-system.co.jp/
10JPA SPECIFICATIONS
ES-0873 Rev.11 Page 1/3