Axial Lead - High Voltage
FEATURES
Filtering – Bypass – Coupling – Blocking
APPLICATIONS
Operating Temperature
Range
Capacitance Tolerance
-40°C to +85°C (10 to 350 WVDC)
-25°C to +85°C (450 WVDC)
+20% at 120 Hz, 20°C
10
16
25
35
50
63
100
160
200
250
350
450
WVDC
Surge
voltage
13
10
20
16
32
25
44
35
63
50
79
63
.1
125
100
.1
SVDC
WVDC
Tan δ
200
160
.2
250
200
.2
300
250
.2
400
350
.25
500
450
.25
Dissipation
Factor
.24
.20
.16
.14
.12
Add .02 for every 1000uF above 1000uF
10 to 100 WVDC
2 Minutes
160 to 450 WVDC
1 Minutes
1 Minute
1 Minute
Leakage current
.03CV or 4uA,
.01CV or 3uA,
CV<1000
CV>1000
Whichever is greater
Whichever is greater
.04CV+100uA
.1CV+40uA
Low
temperature
stability
Impedance ratio
(120 Hz)
WVDC
-25°C to
+20°C
-40°C to
+20°C
10
16
25
35
50
63
100
160
200
250
350
450
4
3
2
2
2
2
2
4
4
4
4
6
10
8
5
4
3
3
3
15
15
15
10
-
2000 hours at 85°C with rated WVDC and ripple current applied
<20% of initial measured value
Capacitance change
Dissipation factor
Leakage current
Load Life
<200% of maximum specified value
<100% of maximum specified value
1000 hours at 85°C with no voltage applied
<20% of initial measured value
Capacitance change
Dissipation factor
Leakage current
Capacitance
Shelf Life
<200% of maximum specified value
<100% of maximum specified value
Frequency (Hz)
Temperature (°C)
uF
50
120
1.0
1.0
1.0
1.0
400
1k
10k
1.65
1.48
1.35
1.25
50k
1.7
+85
1.0
1.0
1.0
1.0
+70
1.3
1.3
1.3
1.3
+60
1.5
1.5
1.5
1.5
+30
1.8
1.8
1.8
1.8
C<10
.8
.8
.8
.8
1.3
1.45
1.36
1.25
1.17
Ripple Current
Multipliers
10<C<100
100<C<1000
C>1000
1.23
1.16
1.11
1.53
1.38
1.28
Special Order Options
D
d
B
5
0.5
0.5
6.3
0.5
0.5
8
0.6
0.5
10
0.6
0.5
12.5
0.6
0.8
16
0.8
0.5
18
0.8
0.5
22
0.8
1.0
25
0.8
1.0
D< 10mm, L1=L+1.5mm Max.
D> 10mm, L1=L+2mm Max.
D1=D+B Max.
mm
Sep-21