Small Size - High Voltage - General Purpose
FEATURES
General Purpose – Bypass – Coupling – Blocking
APPLICATIONS
Operating Temperature Range
Capacitance Tolerance
-40°C to +105°C
+10% at 1 kHz, 25°C
+5% optional
WVDC
VAC
100
63
250
160
400
200
630
220
Peak, AC voltage (50/60 Hz)
For T>+85°C , The voltage must be decreased by 1.25% per °C
Frequency (kHz)
Dissipation Factor
Dissipation Factor (MAX)
25°C
1
10
1.0%
1.5%
Insulation Resistance
Capacitance
<0.33μF
>0.33μF
Insulation Resistance
@25°C (<70% RH) for 1 minute at
100VDC applied
9000 MΩ
3000 MΩxμF
2000 Hours, +85C with 125% of rated voltage
Capacitance Change
Dissipation Factor
<5% of initially measured value
<0.005 at 1kHz and 25°C
Load Life
Insulation Resistance
>50% of maximum specified value
1000 Hours, 93%RH (+/-2%), +40°C and no voltage applied
Capacitance Change
Dissipation Factor
<5% of initially measured value
<0.005 at 1kHz and 25°C
Damp Heat test
Insulation Resistance
>50% of maximum specified value
Self Inductance
Capacitance Drift Factor
<1 nano-Henry per mm of body length and lead length
<1.0% after 2 years at 40°C
Capacitance Temperature Coefficient
+400 ppm/°C, +200ppm/°C
Terminal to Terminal
160% of VDC applied for 2 Seconds and 25°C
Polyester
Dielectric Strength
Dielectric
Construction
Coating
Metallized film
Flame Retardant epoxy resin (UL94V0)
Lead free Tinned Leads
Leads
Special Order Options
L MAX
S+1.0
G MAX
d +0.05
10.5
7.5
1.5
0.6
12
10
1.5
0.6
18.5
15
1.5
0.8
26
31
22.5 27.5
1.5
0.8
1.5
0.8
Oct-23