Effective May 2017
Supersedes March 2008
Technical Data 4322
1025FA
Fast-acting surface mount fuse
Environmental data
• Life test: MIL-STD-202, Method 108A, Test
Condition D
• Load humidity: MIL-STD-202, Method 103B
• Moisture resistance: MIL-STD-202, Method 106E
• Terminal strength: MIL-STD-202, Method 211A
• Thermal shock: MIL-STD-202, Method 107D, air-
to-air
• Case resistance: EIA/IS-722
Product features
• Resistance to dissolution of metallization: ANSI
J-STD-002, Test D
• Mechanical shock: MIL-STD-202, Method 213B
with exceptions per EIA/IS-722 Standard
• High frequency vibration: MIL-STD-202, Method
204D, Test condition D
• Fast-acting surface-mount fuse
• Satisfies the EIA/IS-722 Standard
• Solder immersion compatible
Agency information
•
UL Recognition Guide & File numbers: JDYX2 &
E19180 (250mA - 15A)
• Resistance to solvents: MIL-STD-202, Method
215A
•
CSA Component Acceptance:
File # 053787 C000, Class # 1422 3
Electrical Characteristics
% of Amp Rating
100%
200% (250mA-5A)
250% (250mA-5A fuse)
200% (7-15A fuse)
250% (7-15A fuse)
Opening Time
4 Hours Minimum
5 Seconds Maximum
1 Second Maximum
20 Seconds Maximum
4 Seconds Maximum
Soldering method
• Wave immersion: 260°C, 10 Sec. max.
• Infrared reflow: 260°C, 30 Sec. max.
Ordering
Note: 30vde constant current source required for 200%
• Specify packaging and product code
(i.e., TR2/1025FA250-R)
overload tests on 250mA-1A.
DC Cold
Current
Rating
(amps)
250mA
500mA
750mA
1
1.5
2
2.5
3
3.5
4
5
Voltage
Rating
Typical
Typical
Voltage
Drop‡
Interrupting
Rating (amps)*
250Vac 125Vdc 60Vdc
Product Code
Resistance** (Ω)
Typical
4.7500
1.1500
0.5550
0.2800
0.1140
0.0750
0.0510
0.0384
0.0305
0.0275
0.0195
0.0116
0.0072
0.0056
0.0039
Melting
2
AC
DC
I t†
1025FA250-R
1025FA500-R
1025FA750-R
1025FA1-R
1025FA1.5-R
1025FA2-R
1025FA2.5-R
1025FA3-R
1025FA3.5-R
1025FA4-R
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
60V
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
-
-
-
-
-
-
-
-
-
-
-
-
50
50
50
50
0.1212
0.0415
0.143
1.750
1.460
6.086
8.48
18.15
17.83
23.32
38.74
138
2019mV
1500mV
880mV
560mV
260mV
258mV
232mV
205mV
185mV
190mV
180mV
150mV
146mV
120mV
110mV
1025FA5-R
1025FA7-R
7
1025FA10-R
1025FA12-R
1025FA15-R
10
12
15
60V
60V
60V
-
-
-
457
498
1451
*
AC interrupting rating (measured at designated voltage, 100% power factor random closing); DC interrupting rating (measured at designated voltage, time constant of
less than 50 microseconds, battery source)
** DC cold resistance (measured at ≤10% of rated current)
2
†
Typical Melting I t (measured with a battery bank at rated DC voltage, 10x-rated current, but not exceeding the interrupting rating. Time constant of calibrated circuit less
than 50 microseconds). Test current not to exceed interrupting rating of 50A.
Typical voltage drop (measured at rated current after temperature stabilizes)
‡
• Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at
elevated ambient temperatures.