Fuse Datasheet
501A Series
AEC-Q200 Qualified > High Current 1206 Fast-Acting Fuse
RoHS Pb
Description
The 501A series AEC-Qualified fuses and Halogen free fuse series
are specifically tested to cater to secondary circuit protection
needs of compact auto electronics application.
The general design ensures excellent temperature stability and
performance reliability. The high I2t values which are typical in the
Littelfuse Ceramic Fuse family, ensure high inrush current
withstanding capability.
Features & Benefits
■ OperatingTemperature from
-55ºC to +150ºC
■ Recognized to UL/CSA/NMX
248-1 and UL/CSA/NMX 248-
14
■ 100% Lead-free, RoHS
compliant and
■ AEC-Q200 Qualified
Halogen-free
■ Suitable for both leaded and
lead-free reflow/wave soldering
Additional Information
Applications
Resources
Accessories
Samples
■ Li-ion Battery
■ Battery Management System
(BMS)
■ LED Head-Lights
Agency Approvals
■ Clusters
■ Automotive Navigation
System
Agency
Agency File Number
Ampere Range
■ TFT Display
E10480
29862
10A - 20A
10A - 20A
Electrical Characteristics for Series
% of Ampere Rating
Ampere Rating
OpeningTime at 25ºC
100%
350%
10A – 20A
10A – 20A
4 Hours, Minimum
5 Seconds, Maximum
Electrical Specifications by Item
Agency Approvals
Ampere
Amp
Max.Voltage
Nominal
Nominal
Melting I2t
(A2Sec.) 3
NominalVoltage
Drop at Rated
Current (V) 4
Nominal Power
Dissipation at Rated
Current (W)
Interrupting Rating
(DC) 1
Rating
Code
(A)
Rating
(V)
Resistance
(Ohms) 2
10
12
15
20
010.
012.
015.
020.
32
32
32
32
0.00362
0.00311
0.00250
0.00194
10.385
20.341
39.700
86.360
0.04407
0.04927
0.04843
0.05888
0.4407
0.5912
0.7265
1.1776
x
x
x
x
x
x
x
x
150A @ 32VDC
Notes:
Devices designed to carry rated current for four hours minimum. It is recommended that devices be operated
continuously at no more than 80% rated current. See “Temperature Re-rating Curve” for additional re-rating
information.
1. DC Interrupting Rating tested at rated voltage with time constant <0.5msec.
2. Nominal Resistance measured with <10% rated current.
3. Nominal Melting I2t measured at 1 msec. opening time. For other I2t data refer to chart.
Devices designed to be mounted with marking code facing up.
4. Nominal Voltage Drop measured at rated current after temperature has stabilized and with fuse mounted on
board with 3oz Cu trace.
© 2023 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: GD. 06/20/23