General Purpose Relays
SCHRACK
Rast 5 Power Relay 419 11 (EA/..)
n
n
n
n
n
n
n
2 pole 16 A
Safety mains insulation
Quick connect terminals 6.3 x 0.8 mm
Contact gap > 3 mm
4 kV / 8 mm coil-contact
Snap or screw mounting
Product in accordance to IEC60335-1
Applications
Industrial and domestic appliances, heating controls,
absolute safe power supply disconnection
F0255-CI
Approvals
V
REG.-Nr. 5064 ÜG,
Z
E214024
Technical data of approved types on request
Contact data
Contact configuration
2 NO
bifurcated contacts
full disconnection
250 / 400 VAC
16 A
Contact set
Type of interruption
Rated voltage / max. switching voltage AC
Rated current
Limiting making capacity, max 4 s, duty factor 10%
Contact material
Contact gap
Rated frequency of operation with / without load
25 A
AgCu3
> 3 mm
15 / 600 min-1
Contact ratings
Type
Contact Load
Ambient
temp. [°C]
Cycles
IEC 61810
0419 .. 03
0419 .. 04
0419 .. 03
0419 .. 12 & 13 2 NO
0419 .. 12 & 13 2 NO
0419 .. 12 & 13 2 NO
2 NO
2 NO
2 NO
16 A, 250 VAC, cosϕ=1
85°C
85°C
85°C
85°C
85°C
85°C
250x103
250x103
6x103
12 A, 250 VAC, cosϕ=1
20 A, 250 VAC, cosϕ=1
16 A, 250 VAC, cosϕ=1
12 A, 400 VAC, cosϕ=1
20 A, 250 VAC, cosϕ=1
250x103
250x103
6x103
Coil data
Rated coil voltage range DC coil
AC coil
6...60 VDC
24...400 VAC
1 / 2
Operative range to IEC 61810 DC coil / AC coil
Coil versions, DC-coil
Coil
Rated
voltage
VDC
6
Operate
voltage
VDC
3.5
Release
voltage
VDC
0.4
Coil
resistance
Ohm
50+10%
150+10%
200+10%
800+10%
Rated coil
power
mW
code
10
11
12
13
720
10
6.0
0.7
667
12
24
7.5
15.0
0.9
1.8
720
720
Coil versions, AC-coil
Coil
code
Rated
voltage
VAC
Operate
voltage
VAC
Release
voltage
VAC
Coil
resistance
Ohm
4050+10%
4500+10%
850+10%
Rated coil
power
VA
01
200.50 / 60 Hz
03 220..240.50 / 60 Hz 187.0
160.0
15.0
2.2
16.0
2.2
04 100..120.50 / 60 Hz
80.0
7.0
2.2
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
1
Datasheet Rev. IJ1
Issued 2009/10
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
processing information only
to be used together with the
'Definitions' section in the cat-
alogue or at schrackrelays.com
in the ‘Schrack’ section.
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
Specifications subject to
change.