描述
WISP FAN SPEED CONTROLLER

018W135P 数据手册

 浏览型号018W135P的Datasheet PDF文件第2页 
Wisp II — Speed control for DC fans  
The Wisp II controllers power rating is sufficient  
to control up to three typical 120 mm fans. The  
low voltage version can be used with 12 or 24  
VDC fans. The high voltage version is used with  
48 VDC fans.  
martFan Wisp II is designed  
to control small DC fans. The  
low voltage version includes a  
S
temperature alarm for increased safety. The high  
voltage version accepts a 38 to 75 VDC  
supply voltage range and includes a voltage  
limiter set to 50 VDC.  
Wisp II includes both a temperature sensor  
and control circuit packaged in a probe for conve-  
nient remote or on-fan mounting. The controller  
uses a linear operating principle, applying a smooth  
DC voltage to the fans. It is available for both  
Closed-Loop (temperature regulating) and Open-  
Loop (temperature compensating) applications.  
For additional information see:  
page 13 Design Considerations  
FEATURES  
Noise reduction typically 15 dB(A) at idle speed  
Completely self contained including sensor  
Controls 12, 24 and 48 VDC fans  
3.00 in.  
(76.2mm)  
Low voltage version (018W1XXX) accepts a supply  
voltage range of 11.5 to 30 VDC and includes a temp-  
erature alarm output that can drive logic or a red LED  
2.00 in.  
(50.8mm)  
Temperature  
Sensor  
High voltage version (048W0XXX) accepts a supply  
voltage range of 38 to 75 VDC and includes a voltage  
limiter set to 50 VDC  
0.5 in.  
(12.7mm)  
70ºC maximum operating temperature  
Supplied w ith 15 inch (24 AWG) w ires and  
mounting clamp.  
SPECIFICATIONS  
Type1  
Maximum  
Watts to Fans2  
Part Number  
Control  
Temperature  
Full Speed / Idle Speed  
Temperatures  
Supply  
Voltage Range  
018W135  
018W140  
35°C  
40  
Closed-Loop  
11.5 - 30 VDC  
20 Watts  
203  
N/A  
048W035  
048W040  
35  
40  
Closed-Loop  
38 - 75  
11.5 - 30  
38 - 75  
N/A  
018W135P  
048W035P  
Open-Loop  
Open-Loop  
20  
N/A  
N/A  
35°C/23°C  
35°C/23°C  
203  
1
2
3
Closed-Loop types are installed near equipment exhaust, Open-Loop types at equipment inlet.  
Air temperature of 70°C or less, air velocity of 200 ft/min or greater. See page 13 for derating above 70°C.  
Above 50 VDC supply, power is linearly derated, reaching 10 Watts at 75 VDC.  
U.S. Patents 4,659,290, 4,722,699 and 5,364,026  
CONTROL  
RESOURCES  
INCORPORATED  
E-mail: sales@controlres.com  
Web: w w w.controlres.com  
28  

与018W135P相关器件

型号 品牌 获取价格 描述 数据表
0190010001 MOLEX

获取价格

Avikrimp™ Quick Disconnect, Male, for 18-22 (
0190010002 MOLEX

获取价格

Avikrimp Quick Disconnect, Male, for 18-22 (0.80-0.35), Mylar Tape, Tab 6.35mm (.250") x 0
0190010003 MOLEX

获取价格

Avikrimp™ Quick Disconnect, Male, for 18-22 (
0190010005 MOLEX

获取价格

Avikrimp Quick Disconnect, Male, for 18-22 (0.80-0.35), Mylar Tape, Tab 4.75mm (.187") x 0
0190010006 MOLEX

获取价格

Avikrimp™Quick Disconnect, Male, for 14-16 (2
0190010007 MOLEX

获取价格

Avikrimp™ Quick Disconnect, Male, for 14-16 (
0190010008 MOLEX

获取价格

Avikrimp Quick Disconnect, Male, for 14-16 (2.00-1.30), Box, Tab 4.75mm (.187") x 0.51mm (
0190010009 MOLEX

获取价格

Avikrimp™ Quick Disconnect, Male, for 14-16 (
0190010010 MOLEX

获取价格

Avikrimp Quick Disconnect, Male, for 10-12 (5.00-3.30), Box, Tab 6.35mm (.250") x 0.81mm (
0190010011 MOLEX

获取价格

Avikrimp Quick Disconnect, Male, for 10-12 (5.00-3.30), Mylar Tape,